1 |
02120838-004 |
16-3PH-24/6-GB-R |
Rack Power Distribution Unit,Basic Type-PDU2000-16-3PH-24/6-B5,24*GB 10A+6*GB 16A,11KVA-Right |
|
2 |
02352RFA |
1X160-1X160 |
Supporting IT power distribution single channel (160A) MCCB input + air conditioning power distribution single channel (160A) MCCB input model without output subrack |
|
3 |
02352RFB |
1X160-1X250 |
Supporting IT power distribution single channel (160A) MCCB input + air conditioning power distribution single channel (250A) MCCB input model without output subrack |
|
4 |
02352RFP |
1x160-1x250-C |
Supporting IT power distribution single channel (160A) MCCB input + air conditioning power distribution single (250A) MCCB input model with output enclosure, no air conditioning branch detection |
|
5 |
02352REW |
1x250-1x160 |
Supporting IT power distribution single channel (250A) MCCB input + air conditioning power distribution single channel (160A) MCCB input model without output subrack |
|
6 |
02352REX |
1x250-1x250 |
Supporting IT power distribution single channel (250A) MCCB input + air conditioning power distribution single channel (250A) MCCB input model without output subrack |
|
7 |
02352REU |
2x160-1x160 |
Supporting IT power distribution dual (160A) MCCB input + air conditioning power distribution single (160A) MCCB input model without output subrack |
|
8 |
02352REV |
2x160-1x250 |
Supporting IT power distribution dual (160A) MCCB input + air conditioning power distribution single (250A) MCCB input model without output subrack |
|
9 |
02352REQ |
2x160-2x160 |
supporting IT power distribution dual (160A) MCCB input + air conditioning power distribution dual (160A) MCCB input models ,without output subrack |
|
10 |
02352RED |
2x160-2x250 |
supporting IT power distribution dual (160A) MCCB input + air conditioning power distribution dual (250A) MCCB input models ,without output subrack |
|
11 |
02352RES |
2x250-1x160 |
Supporting IT power distribution dual (250A) MCCB input + air conditioning power distribution single (160A) MCCB input model without output subrack |
|
12 |
02352RET |
2x250-1x250 |
Supporting IT power distribution dual (250A) MCCB input + air conditioning power distribution single (250A) MCCB input model without output subrack |
|
13 |
02352REM |
2x250-2x160 |
supporting IT power distribution dual (250A) MCCB input + air conditioning power distribution dual (160A) MCCB input models ,without output subrack |
|
14 |
02352RER |
2x250-2x250 |
supporting IT power distribution dual (250A) MCCB input + air conditioning 0power distribution dual (250A) MCCB input models ,without output subrack |
|
15 |
02122118-001 |
32-1PH-20/4-GB-R |
Rack Power Distribution Unit-Basic Type-PDU2000-32-1PH-20/4-B11-Output 20*GB 10A+4*GB 16A, GB standard,7.3KVA-Right |
|
16 |
02120765-004 |
32-1PH-9/3-GB-R |
rPDU,Basic Type,PDU2000-32-1PH-9/3-B3,9*GB 10A+3*GB 16A,7.3kVA-Right |
|
17 |
02121737-003 |
32-3PH-12/9-B4-GB-R |
rPDU,Basic Type,PDU2000-32-3PH-12/9-B4,12*GB 10A+9*GB 16A,21kVA-Right |
|
18 |
21141528 |
DKBA41245886.ASM |
Blank panel-Energy-C |
|
19 |
21500989-003 |
DKBA41512108.ASM |
Flexble tail frame for the UPS5000E |
|
20 |
01075302 |
ESM-6440P1 |
Energy Storage Module,ESM-6440P1,64V,40Ah,200mm*592mm*155mm |
|
21 |
53017913 |
FMTABLETCH |
Assembly of the pad and WiFi converter, excluding the pad mounting bracket |
|
22 |
52274254-003 |
NetCol5000-A035H40E0 |
Smart Cooling Product,Air Cooling,Indoor Unit,NetCol5000-A035H,2000H*300W*1200D,Horizontal Air Flow,Down Pipe,Single Power Supply,Cooling Only,International packaging |
|
23 |
52274254-001 |
NetCol5000-A035H40E2 |
Smart Cooling Product,Air Cooling,Indoor Unit,NetCol5000-A035H,2000H*300W*1200D,Horizontal Air Flow,Up&Down Pipe,Dual Power Supply,Cooling Only,International packaging |
|
24 |
52274254-002 |
NetCol5000-A035H4WE0 |
Smart Cooling Product,Air Cooling,Indoor Unit,NetCol5000-A035H,2000H*300W*1200D,Horizontal Air Flow,Down Pipe,Single Power Supply,Heating&Humidifier,International packaging |
|
25 |
52274254 |
NetCol5000-A035H4WE2 |
Smart Cooling Product,Air Cooling,Indoor Unit,NetCol5000-A035H,2000H*300W*1200D,Horizontal Air Flow,Up&Down Pipe,Dual Power Supply,Heating&Humidifier,International packaging |
|
26 |
02115174-001 |
NetHos-M FR42611W |
M-type rack, 600 mm (W) x 1100 mm (D) x 2000 mm (H), 42 U |
|
27 |
02115065-001 |
NetHos-M FR42612W |
M-type rack, 600 mm (W) x 1200 mm (D) x 2000 mm (H), 42 U |
|
28 |
02115182-001 |
NetHos-M FR42812W |
M-type rack, 800 mm (W) x 1200 mm (D) x 2000 mm (H), 42 U |
|
29 |
02115176-001 |
NetHos-M FR47612W |
M-type rack, 600 mm (W) x 1200 mm (D) x 2200 mm (H), 47 U |
|
30 |
02115184-001 |
NetHos-M FR47812W |
M-type rack, 800 mm (W) x 1200 mm (D) x 2200 mm (H), 47 U |
|
31 |
02405344 |
PDU8000-0250ACV4-CBA917 |
Power Distribution Cabinet,PDU8000-0250ACV4-CBA917,380V,3PH,50Hz,250A |
|
32 |
02405343 |
PDU8000-0400ACV4-CBA916 |
Power Distribution Cabinet,PDU8000-0400ACV4-CBA916,380V,3PH,50Hz,400A |
|
33 |
02115385-005 |
PDU8000-ACV4-CCA-02 |
Integrated power distribution cabinet frame-600mm(W)*1200mm(D)*2000mm(H) |
|
34 |
02115384-002 |
PDU8000-ACV4-CCA-1 |
Integrated power distribution cabinet frame-600mm(W)*1100mm(D)*2000mm(H) |
|
35 |
02312TMX |
PM30K-V4S |
Function Module,30kVA power module,2U,UPS5000-E |
|
36 |
02312TDM |
SmartLi-512V-80AH-F-01 |
SmartLi-Lithium battery cabinet-full configuration (with monitor) |
|
37 |
02312TDM-001 |
SmartLi-512V-80AH-S-01 |
SmartLi-Lithium battery cabinet-standard configuration (without monitor) |
|
38 |
02312QAD |
UIM20A |
Ecc800-Pro-Expansion module-Eight RS485/AI/DI multiplex ports |
|
39 |
02312TVY |
UPS5000-E-125K-HABBS |
Integrated UPS Cabinet, UPS5000-E-125K-HABBS-01, 380/400/415V, MCCB Input, Without Air-conditioning Distribution Module |
|
40 |
02312TWA |
UPS5000-E-125K-HASBS |
Integrated UPS Cabinet, UPS5000-E-125K-HASBS-01, 380/400/415V, ATS Input, Without Air-conditioning Distribution Module |
|
41 |
02312TVW |
UPS5000-E-60K-HABBS |
Integrated UPS Cabinet, UPS5000-E-60K-HABBS, 380/400/415V, MCCB Input, Without Air-conditioning Distribution Module |
|
42 |
02312TVX |
UPS5000-E-60K-HASBS |
Integrated UPS Cabinet, UPS5000-E-60K-HASBS, 380/400/415V, ATS Input, Without Air-conditioning Distribution Module |
|
43 |
04080642 |
UPSCU5KUMC03 |
Monitor&Alarm Cable,5m,Power supply |
|